SKF Microlog Analyzer CMXA 75 GX Series Vibration Analyzer kit. Comes along Version 4.05 cd, cables, 4gb sandisk SD card, plug charge, some documents and carrying case. It is working as it should.
Condition: UsedSKF Microlog Analyzer CMXA 75 GX series Vibration Analyzer kit in very good condition. It is working as it should. Meter has rubber protection case. We offer with a 30-day money back guarantee.
Package includes:
The SKF Microlog GX series are high performance, one to three channel, routebased portable data collector / FFT analyzers that provide unmatched versatility and functionality in a rugged, industrial design. Developed for use in a wide range of industries, the SKF Microlog GX series is approved for use in hazardous environments requiring ATEX, IECEx and Class I Division 2 certifications.
Key features
SKF CMXA 75 GX Specifications
| Input sources |
|
|
| Preprocessing | Enveloper (demodulator) | With four selectable input filters for enhanced bearing and gear mesh fault detection |
| Filter selection | 5 Hz to 100 Hz | |
| 50 Hz to 1 kHz | ||
| 500 Hz to 10 kHz | ||
| 5 kHz to 40 kHz | ||
| Input parameters | Tachometer: TTL / analogue programmable to ±25 V | |
| RPM range 1 to 99 999 | ||
| Tachometer power supply output +5 V at 100 mA | ||
| Input over-voltage protection | AC ±50 V peak ; DC ±50 V sustained | |
| Dynamic range | >90 dB (24 bit ADC sigma-delta) | |
| Input connectors | CH1: Six pin Fischer, CH1, CH2, CH3 | |
| CH2: Six pin Fischer, CH2, CH3 | ||
| USB host / CHR / headphone: USB keyboard, CHR, headphones | ||
| USB Device / power / trigger: Seven pin Fischer trigger in, trigger tachometer power supply, USB COMMS, charger | ||
| Input signal range | ±25 V maximum | |
| Data processing and storage | Microprocessor | Marvell 806 MHz PXA320 |
| Internal storage | 128 MB (capable of storing approximately 4 000 spectra) | |
| External storage | SD memory card up to 16 GB | |
| Measurement | Range | Route measurements: DC to 80 kHz |
| Analyzer measurements: DC to 80 kHz | ||
| Averaging | 1 to 255 time averages, 1 to 4 096 spectral averages | |
| Averaging type | RMS, Exponential, Peak Hold, and Time Sync | |
| Cursor | Fixed and cursor lock. Single, harmonic and peak pick | |
| Trigger modes | Free run or external trigger (trigger slope and amplitude) | |
| Resolution | Programmable 100, 200, 400, 800, 1 600, 3 200, 6 400, 12 800, and 25 600 lines | |
| Measurement windows | Hanning, flat top and rectangular | |
| Multi-point automation | Up to 12 measurements can be listed for one button push automated data collection at each measurement location | |
| Data displays | Single and dual channel spectrum, single and dual channel time, phase table, process, orbit, cross channel phase | |
| Simultaneous spectrum, time waveform, peak hold averaging | ||
| Up to 12 bands (fixed or order base) downloadable from host software | ||
| Power | Battery | Li-ion smart battery pack |
| Operating time | 8 hours continuous operation minimum | |
| Physical data | Dedicated keys | Up, down, right, and left two enter keys for right and left hand operation, four function buttons |
| Hot keys | Peak find, harmonic, expand | |
| LCD screen | Color 1/4 VGA 320 x 240 pixels (54 x 72 mm) viewable | |
| Case | High impact ABS with IP 65 dust and splash rating | |
| Communication | USB | |
| Drop test | 2 m (6.6 ft.), to MIL STD 810 specifications | |
| Size (H x W) | Narrowest point: 186 x 93 mm (7.4 x 3.7 in.) | |
| Widest point: 186 x 134 mm (7.4 x 5.4 in.) | ||
| Weight | 715 g (1.6 lb.) | |
| Environmental | Hazardous locations | CSA, Class I, Division 2, Groups A, B, C, D (special conditions per installation drawing 090-22600, reference Appendix D, Safety Instructions) |
| ATEX: II 3 G Ex ic IIC T4 Gc (Ta = -10 °C to +50 °C) (special conditions per installation drawing 090-22861-1, reference Appendix D, Safety Instructions) | ||
| IECEx: Ex ic IIC T4 Gc (Ta = -10 °C to +50 °C) | ||
| CE rated | Special conditions per certifications | |
| IP Rating | IP 65 | |
| Operating temperature | –10 to +50 °C (14 to 122 °F) | |
| Storage temperature | –20 to +60 °C (–4 to +140 °F) | |
| Humidity | 95% non-condensing | |