Tektronix
Tektronix DPO5204 Digital Phosphor Oscilloscope
Sell used Tektronix DPO5204 4 + 16 Ch 2 GHz 10 GS/s Digital Phosphor Oscilloscope. Operating System Upgraded to Windows 10, running on a 500 GB Solid State Drive (vs Windows 7 on 160 GB). Both Drives are provided.
USD 9,700.00
- Condition
- Used
- Availability
- In Stock
- Brand
- Tektronix
- Category
- Analyzer
Product Description
Sell used Tektronix DPO5204 4 + 16 Ch 2 GHz 10 GS/s Digital Phosphor Oscilloscope. Operating System Upgraded to Windows 10, running on a 500 GB Solid State Drive (vs Windows 7 on 160 GB). Both Drives are provided.
Key Performance Specifications
- 2 GHz Bandwidth Models
- Up to 10 GS/s Real-time Sample Rate on One or Two Channels and up to 5 GS/s on All Four Channels
- Up to 250 Megapoint Record Length with MultiView Zoom™
- >250,000 wfms/s Maximum Waveform Capture Rate with FastAcq™
- FastFrame Segmented Memory Acquisition Mode with >310,000 Frames per Second Capture Rate
- Standard Passive Voltage Probes with Less than 4 pF Capacitive Loading and 500 MHz or 1 GHz Analog Bandwidth
- User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy
- Suite of Advanced Triggers
Ease-of-Use Features
- Wave Inspector® Controls provide Easy Navigation and Automated Search of Waveform Data
- MyScope® Custom Control Windows and Right Mouse Click Menus for Exceptional Efficiency
- 53 Automated Measurements, Waveform Histograms, and FFT Analysis for Simplified Waveform Analysis
- TekVPI® Probe Interface supports Active, Differential, and Current Probes for Automatic Scaling and Units
- 10.4 in. (264 mm) Bright XGA Display with Touch Screen
- Small Footprint and Lightweight – Only 8.12 in. (206 mm) Deep and Less than 15 lb. (6.7 kg)
Connectivity
- Two USB Host Ports on the Front Panel and Four on the Rear Panel for Quick and Easy Data Storage, Printing, and Connecting USB Peripherals
- USB Device Port on the Rear Panel for Easy Connection to a PC or GPIB Control with an Adapter
- Integrated 10/100/1000BASE-T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector
- Microsoft® Windows 7 64-bit Operating System for Easy Connectivity and Integration into Your Environment
- LXI Class C Compliant
Mixed Signal Design and Analysis (MSO Series)
- Automated Triggering and Decode on Parallel Buses
- Per-channel Threshold Settings
- MagniVu™ High-speed Acquisition provides 60.6 ps Fine Timing Resolution on Digital Channels
Optional Serial Triggering and Analysis
- Automated Serial Triggering and Decode Options for I2C, SPI, RS-232/422/485/UART, and USB
- Automated Serial Decode and Vehicle Network Monitoring of CAN and LIN
Optional Technology Specific Analysis
- Software Solutions provide Built-in Domain Expertise for Ethernet and USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagrams, Power, and DDR Memory Bus Analysis
- Limit and Mask Testing provide Quick Insight into Signal Characteristics
Tektronix DPO5204 Specification
| Input Channels | 4 |
| Analog Bandwidth (–3 dB) | 2 GHz |
| Maximum Sample Rate (1 or 2 channels) | 10 GS/s |
| Rise Time | 175 ps |
| DC Gain Accuracy | ±1.5%, derated at 0.10%/°C above 30 °C |
| Bandwidth Limits | Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, and 20 MHz |
| Input Coupling | AC, DC |
| Input Impedance | 1 MΩ ±1%, 50 Ω ±1% |
| Input Sensitivity | 1 MΩ : 1 mV/div to 10 V/div 50 Ω : 1 mV/div to 1 V/div |
| Vertical Resolution | 8 bits (11 bits with Hi Res) |
| Max Input Voltage, 1 MΩ |
|
| Max Input Voltage, 50 Ω | 5 VRMS, with peaks ≤ ±20 V |
| Position Range | ±5 divisions |
| Delay between any Two Channels (Typical) | ≤100 ps (50 Ω, DC coupling and equal V/div at or above 10 mV/div) |
| Offset Range | 1 mV/div - 50 mV/div 1 MΩ : ±1 V 50 Ω : ±1 V 50.5 mV/div - 99.5 mV/div 1 MΩ : ±0.5 V 50 Ω: ±0.5 V 100 mV/div - 500 mV/div 1 MΩ: ±10 V 50 Ω: ±10 V 505 mV/div - 995 mV/div 1 MΩ: ±5 V 50 Ω: ±5 V 1 V/div - 5 V/div 1 MΩ: ±100 V 50 Ω: ±5 V 5.05 V/div - 10 V/div 1 MΩ: ±50 V 50 Ω: NA |
| Offset Accuracy | ±(0.005 × |offset – position| + DC Balance) Note: Both position and constant offset term must be converted to volts by multiplying by the appropriate volts/div term |
| Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical) | ≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated BW |
| Options |
|
Operating System Upgraded to Windows 10, running on a 500 GB Solid State Drive (vs Windows 7 on 160 GB). Both Drives are provided.
Software/firmware is updated to current and latest version. It does come in the Tek packaging/box and manual.
Includes:
- Tektronix DPO5204 unit
- Tek packaging / Box
- Manual
Download
Tektronix DPO5204/MSO5204 Mixed Signal Oscilloscopes DataSheet.PDF
Customer Reviews
Rated 4.0 out of 5 based on 15 reviews.