Fluke 435 Power Quality Analyzer

Used Fluke 435 Three Phase Power Quality Analyzer

Condition: Used
$2,400

Selling a used Fluke 435 Three Phase Power Quality Analyzer i430 FLEX Probe with Advanced Functions and all installed options. Unit is used with some signs of previous use and overall in a good cosmetic condition. Thoroughly tested with a 60-day warranty and 30-day money back guarantee.

Package includes:

  • Fluke 435 Power Quality Analyzer
  • Fluke AC to DC Power Supply Charger
  • Fluke OC4USB Optical Communication Cable
  • 5 x Fluke Alligator Clamps (4 Black 1 Green)
  • 5 x Probe Cable Lead Set (4 Black 1 Green)
  • 4 x Fluke i430 FLEX Current Probes Various Color Wire Markers
  • Hard Transport Case
  • 60-day warranty
  • 30-day money back guarantee

The Fluke 435 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in three- and single-phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. The new IEC standards for flicker, harmonics and power quality are built right in to take the guess work out of power quality

Fluke 435 has additional features such as Mains Signaling, Logging, 0.1 % voltage input accuracy acc. to IEC61000-4-30 2003 Class A, extra memory to store Logging Data, Power Log software, flexible current clamps, and a heavy duty trolley style case.

Fluke 435 Specifications

Power
Line power Switchable 115 V, 230 V adapter with country specific plug
Power adapter output voltage 15 V dc to 23 V dc; use only power adapter BC430
Battery power Rechargeable NiMH BP190 (installed)
Battery operating time > 7 hours
Battery charging time 4 hours, 8 hours for/006 version (instrument off)
Power saving Adjustable time for dimmed backlight with on screen power indicator
Standards
Measurement methods used IEC61000-4-30 class A
Measurement performance Fluke 435 IEC61000-4-30 Class A, Fluke 434 IEC61000-4-30 Class B
Power quality EN50160
Flicker IEC 61000-4-15
Harmonics IEC 61000-4-7
Cross Talk
Between V inputs -60 dB @ Fnominal
Voltage to current input -95 dB @ Fnominal
Safety
Compliance IEC/EN61010-1-2001
CAN/CSA C22.2 No 61010-1-04
UL std No 61010-1
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements
Rated: 600V CAT IV / 1000V CAT III Pollution Degree 2
Max voltage on banana input 1000 V CAT III/600 V CAT IV
Max voltage on current BNC input 42 Vpeak
Environmental
Operating temperature 0 °C to +50 °C (32 °F to 122 °F) battery only, 0 °C to +40 °C (32 °F to 104 °F) with adapter, within spec +15 °C to +35 °C (59 °F to 95 °F)
Storage temperature -20 °C to +60 °C (-4 °F to +140 °F)
Humidity 10 °C to 30 °C: 95 % RH non-condensing
30 °C to 40 °C: 75 % RH non-condensing
40 °C to 50 °C: 45 % RH non-condensing battery only
Maximum operating altitude 3000 m. Derate to 1000 V CAT II/600 V CAT III/300 V CAT IV above 2000 m
Maximum storage altitude 12 km
Printers and Interface
Type Serial, optically isolated. Compatible with PM9080 (RS-232) or OC4USB (USB)
Baud rate 1200, 2400, 9600 to 57 kb
Print out facility (B&W only) Via optional adapter PM9080 or PAC 91
Print protocol Epson FX LQ, Deskjet, LaserJet , DPU-414 or PostScript
Dimension 256 mm x 169 mm x 64 mm
Weight 2 kg

Download

Fluke 435 User Manual.pdf