Used Fluke 435 Three Phase Power Quality Analyzer
Condition: UsedSelling a used Fluke 435 Three Phase Power Quality Analyzer i430 FLEX Probe with Advanced Functions and all installed options. Unit is used with some signs of previous use and overall in a good cosmetic condition. Thoroughly tested with a 60-day warranty and 30-day money back guarantee.
Package includes:
The Fluke 435 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in three- and single-phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues. The new IEC standards for flicker, harmonics and power quality are built right in to take the guess work out of power quality
Fluke 435 has additional features such as Mains Signaling, Logging, 0.1 % voltage input accuracy acc. to IEC61000-4-30 2003 Class A, extra memory to store Logging Data, Power Log software, flexible current clamps, and a heavy duty trolley style case.
Fluke 435 Specifications
| Power | |
| Line power | Switchable 115 V, 230 V adapter with country specific plug |
| Power adapter output voltage | 15 V dc to 23 V dc; use only power adapter BC430 |
| Battery power | Rechargeable NiMH BP190 (installed) |
| Battery operating time | > 7 hours |
| Battery charging time | 4 hours, 8 hours for/006 version (instrument off) |
| Power saving | Adjustable time for dimmed backlight with on screen power indicator |
| Standards | |
| Measurement methods used | IEC61000-4-30 class A |
| Measurement performance | Fluke 435 IEC61000-4-30 Class A, Fluke 434 IEC61000-4-30 Class B |
| Power quality | EN50160 |
| Flicker | IEC 61000-4-15 |
| Harmonics | IEC 61000-4-7 |
| Cross Talk | |
| Between V inputs | -60 dB @ Fnominal |
| Voltage to current input | -95 dB @ Fnominal |
| Safety | |
| Compliance | IEC/EN61010-1-2001 |
| CAN/CSA C22.2 No 61010-1-04 | |
| UL std No 61010-1 | |
| Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements | |
| Rated: 600V CAT IV / 1000V CAT III Pollution Degree 2 | |
| Max voltage on banana input | 1000 V CAT III/600 V CAT IV |
| Max voltage on current BNC input | 42 Vpeak |
| Environmental | |
| Operating temperature | 0 °C to +50 °C (32 °F to 122 °F) battery only, 0 °C to +40 °C (32 °F to 104 °F) with adapter, within spec +15 °C to +35 °C (59 °F to 95 °F) |
| Storage temperature | -20 °C to +60 °C (-4 °F to +140 °F) |
| Humidity | 10 °C to 30 °C: 95 % RH non-condensing |
| 30 °C to 40 °C: 75 % RH non-condensing | |
| 40 °C to 50 °C: 45 % RH non-condensing battery only | |
| Maximum operating altitude | 3000 m. Derate to 1000 V CAT II/600 V CAT III/300 V CAT IV above 2000 m |
| Maximum storage altitude | 12 km |
| Printers and Interface | |
| Type | Serial, optically isolated. Compatible with PM9080 (RS-232) or OC4USB (USB) |
| Baud rate | 1200, 2400, 9600 to 57 kb |
| Print out facility (B&W only) | Via optional adapter PM9080 or PAC 91 |
| Print protocol | Epson FX LQ, Deskjet, LaserJet , DPU-414 or PostScript |
| Dimension | 256 mm x 169 mm x 64 mm |
| Weight | 2 kg |
Download