Used SIUI SyncScan 2 Phased Array TOFD Ultrasonic Flaw Detector

Used SIUI SyncScan 2 Phased Array 16:64 & TOFD Inspection Ultrasonic Flaw Detector NDT with probes.

Condition: Used
$7,300

Up for sale Used SIUI SyncScan 2 Phased Array & TOFD Inspection Ultrasonic Flaw Detector NDT with probes, Calibrated. Ultrasonic flaw detector with 16:64 PAUT and TOFD, which can maximize your efficiency for PA and TOFD. Phases Array, Flat Weld Groove, TOFD Enabled Licences. Comes with a 90-day warranty and 30-day money back guarantee.

Package includes:

  • SIUI SyncScan 2 Unit
  • Battery
  • Power Adapter
  • 4.0L16-0.5-9 Phased Array Probe
  • P2.5-20L UT Probe
  • T5-6L-UN TOFD Probe
  • TFN-70-UN-I Wedge for TOFD Probe
  • TFB-60-UN-I Wedge for TOFD Probe
  • TFB-70-UN-I Wedge for TOFD Probe
  • 8N00L-20 Wedge for Phased Array Probe
  • Probe Cables
  • Software (CD)
  • Hard Case
  • 90-day warranty
  • 30-day money back guarantee

Features

  • 8.4” LCD with resolution 800×600 pixels
  • Support PA/TOFD/UT, suitable for weld, forging and plate inspection.
  • Upgradeable from conventional UT to phased array or TOFD
  • 1 - 4 channel TOFD for Selection
  • Support PR mode, focusing on pipe corrosion inspection when with high-end dual-crystal PA probe.
  • Removable electric fan: cool down the system when it works in high temperature.
  • System ports: encoder, VGA, standard SD card, USB 2.0/3.0
  • IP rate: IP65

General Specification

Display 8.4” high brightness TFT LCD, 800 x 600
Data Storage Standard SD card (16G)
USB Connector 2 pcs
Ethernet Connector 1 pc
Video Output VGA port
Encoder Connector 1 pc (14-core)
WiFi 1pc, Build-in
Battery Lithium battery
Battery Capacity 7.5 Ah/pc, operation time more than 4 hours for PAUT, 5 hours for UT/TOFD.
Power Supply AC 100-240V 50Hz/60Hz
Adaptor Output 15V DC
Power 20VA
Operation Temperature -10 C - 45 °C
Storage Temperature -20 C - 60 °C
IP Code IP65
Dimension 284 x 220 x 90 mm
Weight 3.75 kg with battery


Technical Specification for 16:64 PAUT and TOFD to achieve simultaneous inspection of PA & TOFD

  Conventional UT Phased Array TOFD

SYSTEM

No. of Channel 1 16 1/2/4
Probe Connector LEMO 00, 2 pcs Tyco, 1 pc LEMO 00, 2 pcs
Max. Supporting Elements 2 64 2-8
PR (Pitch & Catch) Function Adjustable 20-2000Hz, step: 20Hz 100Hz-20KHz, step:100Hz Adjustable 20-2000Hz, step: 20Hz
Pulser Negative square Bi-polar square Negative square
PRF Adjustable 10 - 2000Hz
Step 20Hz
100Hz - 10KHz
Step 100/200/500/1000Hz
Adjustable 10 - 2000Hz
Step 20Hz
Pulse Voltage 50V - 500V, min. step 1V 10-100V, step 10V/20V 50V - 500V, min. step 1V
Pulse Energy - 4 levels -
Pulse Frequency - 2-10MHz, step 0.5MHz -
Pulse Width 30-1000ns, step 10ns - 30-1000ns, step 10ns
Damping 25/75/200/1000Ω, 4 levels - 25/75/200/1000Ω, 4 levels
Pulse Delay - 0-20µs, resolution 5ns -
Pulse Focusing - Single point focusing -

RECEIVER

Gain 0-110dB, Step 0.5/2/6/12dB 0-80dB, Step 0.1/0.5/2/6/12dB 0-110dB, Step:0.5/2/6/12dB
Bandwidth 0.5-20MHz (-3dB) 0.7-20MHz (-3dB) 0.5-20MHz (-3dB)
A/D Sampling Rate 170MHz/12bit 100MHz/12bit 170MHz/12bit
Rectification Positive/Negative/Full/RF Positive/Negative/Full/Filter RF
Receiver Delay - 0-20µs, resolution 2.5ns -
Receiver Focusing - Max. Range 1008 foci per scan line -
Filter Digital: 10 levels
1-4/0.5-10/2-20/1/2.5/4/5/10/13/15MHz
Analog: 4 levels
3/5/10/Full MHz
6 levels
0.7-4/2.5-7/4-8.5/7-10/9-15/0.7-20Mhz
6 levels
0.5-5/0.5-10/3.5-10/0.5-15/5-15/0.5-20MHz
Reject 0-80%, step 1% - -

SCAN

Scan Type A/B A/S/L/C/D A/TOFD
Trigger Mode - Time-based/Encoder Encoder
Scan Length - Max.3m (encoder precision:0.5mm) Max.90m (encoder precision:0.5mm, 4-ch TOFD working simultaneously)
Focal Laws - Max. 512 lines -
Scan Angle Range - -89°-+89°, step 1° -
Angle Spacing - 0.1°-5°, step 1° -
Line Average - - 4 levels, 1/2/4/8
Focus Position - 6-500mm, step 1mm -

BASIC

Range 0-15000mm, Min. display range 5mm 0-1000mm, Min. step 0.01mm
Min. display range 3mm
0-15000mm, Min. step 0.1mm
Material Velocity 500-15000m/s, Min. step 1m/s 500-15000m/s, Min. step 1m/s 500-15000m/s, Min. step 1m/s
Display Delay 0-1000mm, Min. step 0.01mm 0-1000mm, Min. step 0.01mm 0-1000mm, Min. step 0.01mm
Probe Zero 0-200µs, Min. step 0.01µs - 0-200µs, Min. step 0.01µs
Probe Flank 0-100mm, step 0.01mm - 0-100mm, step 0.01mm
Wizard DAC, AVG/DGS, Angle calibration, Auto calibration (velocity, Zero), Plate, Weld, forging scan. Scan wizard velocity/delay/sesitivity/TCG calibration wizard Scan wizard, PCS Calculation, Probe Zero Calibration, Ultrasound Parameter, Time Window
Calibration Zero, Velocity Zero, Velocity, Delay, Sesitivity, TCG -
Test Point Selection Peak/ Flank/ J Flank Peak/ Flank/ J Flank/ G Flank -
Measurement Three gates: to measure echo amplitude, amplitude dB difference, sound path, Ra/Da Three gates: to measure echo amplitude, sound path, Ra/Da
Two measure cursors: to measure horizontal/vertical and distance between cursors.
Flaw height and length mesurement.
Gate Start Full range Full range -
Gate Width Full range Full range -
Gate Thresh 10'90%, step 1% 10'90%, step 1% -

MEASUREMENT

Curve Function AVG/DGS & DAC: Max. 6 lines & 16 points for each line TCG & DAC: Max. 6 lines, Max. 16 points for each line -
Auxiliary Function Full screen, coordinate swtch (sound path/ depth/ horizontal), auto gain (single/ continuous), second leg color, wave compare, gate expansion, wave filling, peak envelope, auto freeze, Cineloop, screenshow, crack height measurement, API, AWS, UT probe spectrum analysis, TCG, B scan, flat weld groove. Auto gain: single/ continuous
Auto search: search the highest echo amplitude scan line within gate range in B scan. (available when in R view)
Group function: Max. 6 groups
Flat weld groove
C scan in-depth
Probe element testing
-
Alarm Signal Signal and sound alarm: positive/ negative Signal and sound alarm: positive/ negative -
Display Measure Value - 8 positions can be user-defined -
Data Analysis - Image mode switch, image gate dynamic reconstruction and report generation LW/BW straightening/ removal, contrast adjust, gain adjust, zoom

TESTING INDEX

Time Base Linearity ≤ 0.5% - -
Vertical Linearity ≤ 3% - -
Amplitude Linearity ≤ ±2% - -
Attenuator Precision 20dB ± 1dB - -
Dynamic Range ≥ 32db    

SOFTWARE

Optional Software API PA Groups Can be upgraded to 2-ch TOFD
AWS Flat Weld Groove Can be upgraded to 4-ch TOFD
TCG Angle Weld Solution Can be upgraded to 4-ch TOFD
B scan Simultaneous Display of PAUT and TOFD SAFT
Flat Weld Groove C Scan In-Depth -
CSC (Curved Surface Correction) Corrosion Solution -